Question
In calibrating the Combo Tester (model # 41203) we observed that the standard called for in Tech Brief PS-2058, [the calibration box] model# 41230 does not provide a 4 to 1 [accuracy] ratio [which is the industry standard]. The Combo Tester has a rated accuracy of 5%, while the standard has a rated accuracy of 10%. Is this a typo or are these accuracy's correct? - Bob, Nashua, NH
Answer
This was a typo. The correct accuracies are: Combo Tester, 10% Calibration Box, 2%. Thanks for your feedback.