MENU
Toggle navigation
Products
AmeriVacS Vacuum Sealers
AVN Series
AVS Series
CAVN Series
CAVS Series
AVC Series
AVP Series
Atrix Vacuums
Benchpro Workstations
Cleanroom
ESD Turntable
Field Service
Floor Mats
Rubber Floor Mats
Garments, Gloves, and Booties
Disposable Smocks
Gloves, Dissipative
Booties
Gibo Kodama Chairs
Grounding Hardware
Drag Chain
Ground Adapters
Ground Point Adapters
Wristband Adapters
Banana Plug Attachments
Closeout Grounding Hardware and Adapters
Ionizers
Ionizers for Critical Environments
Ionizers for Electronics Production
Bench Top Ionizers
Data Converters
Kasuga
MicroCare™ ESD Wipes
Personnel Grounding
Foot Grounders
Economy Heel Grounders
General Use Foot Grounders
Premium Foot Grounders
Closeout Foot Grounders
Wrist Straps
Dual Wire Wrist Straps and Coil Cords
Single Wire Wrist Straps and Coil Cords
Closeout Wrist Straps and Coil Cords
Static Clean
Balanced Ionizer Blower
Particle Trap
SelecTile ESD™ Floor Tile
Static Dynamics Cart Grounding
Statico
Continuous Monitoring
Foot Grounders
Gloves
Grounding Hardware
Bench Mounts
Common Point Grounds
Dome Style
Standard Snap Style
Snaps
Ionization
Measurement
Resistance Meters
Static Field Meters
Monitors
Mats
2-Layer Rubber
Single-Layer Vinyl
3-Layer Vinyl
Multiple-Layer Vinyl
Anti-Fatigue
V-Grove
Packaging
Personnel Grounding Testers
Tape
Clear
Clear with ESD Symbols
Grid
High Temperature
Red
Isle and Floor
Wrist Straps and Coil Cords
Disposable
Dual Conductor
Elastic
Metal
Velcro
Tacky Mats
Testing and Monitoring
Calibration Units
Continuous Monitors
Dual Wire Resistance Monitors
Single Wire AC Capacitance Monitors
Field Meters
Periodic Wrist Strap and Footwear Testers
Combo Wrist Strap & Footwear Testers
Footwear Testers
Closeout Testers and Monitors
Trustat®
Grounding Products
Heel Grounders
Ionizers
Smocks
Worksurface Mats
Wrist Straps and Coil Cords
Workstation Accessories
Dissipative Chair Cover
Workstation Mats
Dissipative Rubber Mat
Tray Liners
Mat Kits
Factory Closeouts
Closeout - Workstation Mats
Closeout - Accessories
Closeout Foot Grounders
Closeout Smocks, Gloves, and Finger Cots
Closeout - Packaging and Handling
Closeout Antistatic Tape
Closeout Labels
Closeout Metal In Bags
Closeout ESD Bags
Closeout Workstation Pouches
Closeout Testers and Monitors
Closeout Wrist Straps and Coil Cords
Closeout - Miscellaneous Coil Cords
Closeout - 4mm Single Wire Wrist Straps and Coil Cords
Closeout - 4mm Dual Wire Wrist Straps and Coil Cords
Closeout - 7mm Single Wire Wrist Straps and Coil Cords
Closeout - 7mm Dual Wire Wrist Straps and Coil Cords
Closeout - 10mm Single Wire Wrist Straps and Coil Cords
Closeout - 10mm Dual Wire Wrist Straps and Coil Cords
New Products
Resources
Overstock
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
768
List All Questions
Search
List by Category
Question
When working around high line voltage equipment how important is it to have a one megohm resistor in the circuit? - Anonymous
Answer
When working with voltages over 250 VAC, ESD personnel grounding should not be used, rather ionization may be required to neutralize electrostatic charges. As important as ESD control is, it is of secondary importance compared to employee safety. Questions regarding safety should be answered by the facility’s safety officer. The safety officer and ESD Coordinator should be aware of this information.ANSI/ESD S20.20 -1999 states: “Paragraph 5. PERSONNEL SAFETY - The Procedures and equipment described in this document may expose personnel to hazardous electrical conditions. Users of this document are responsible for selecting equipment that complies with applicable laws, regulatory codes and both external and internal policy. Users are cautioned that this document cannot replace or supersede any requirements for personnel safety. Ground fault circuit interrupters (GFCI) and other safety protection should be considered wherever personnel might come into contact with electrical sources. Electrical hazard reduction practices should be exercised and proper grounding instructions for equipment must be followed.” There is always a safety concern when working around high voltage. All electrical wiring and ground connections should adhere to the National Electrical Code (NEC) as governed by OSHA. Per ESD Association ADV-2.0-1994, Safety rules for working with high voltages should dictate the design of the workstation.