MENU
Toggle navigation
Products
AmeriVacS Vacuum Sealers
AVN Series
AVS Series
CAVN Series
CAVS Series
AVC Series
AVP Series
Atrix Vacuums
Benchpro Workstations
Cleanroom
ESD Turntable
Field Service
Floor Mats
Rubber Floor Mats
Garments, Gloves, and Booties
Disposable Smocks
Gloves, Dissipative
Booties
Gibo Kodama Chairs
Grounding Hardware
Drag Chain
Ground Adapters
Ground Point Adapters
Wristband Adapters
Banana Plug Attachments
Closeout Grounding Hardware and Adapters
Ionizers
Ionizers for Critical Environments
Ionizers for Electronics Production
Bench Top Ionizers
Data Converters
Kasuga
MicroCare™ ESD Wipes
Personnel Grounding
Foot Grounders
Economy Heel Grounders
General Use Foot Grounders
Premium Foot Grounders
Closeout Foot Grounders
Wrist Straps
Dual Wire Wrist Straps and Coil Cords
Single Wire Wrist Straps and Coil Cords
Closeout Wrist Straps and Coil Cords
Static Clean
Balanced Ionizer Blower
Particle Trap
SelecTile ESD™ Floor Tile
Static Dynamics Cart Grounding
Statico
Continuous Monitoring
Foot Grounders
Gloves
Grounding Hardware
Bench Mounts
Common Point Grounds
Dome Style
Standard Snap Style
Snaps
Ionization
Measurement
Resistance Meters
Static Field Meters
Monitors
Mats
2-Layer Rubber
Single-Layer Vinyl
3-Layer Vinyl
Multiple-Layer Vinyl
Anti-Fatigue
V-Grove
Packaging
Personnel Grounding Testers
Tape
Clear
Clear with ESD Symbols
Grid
High Temperature
Red
Isle and Floor
Wrist Straps and Coil Cords
Disposable
Dual Conductor
Elastic
Metal
Velcro
Tacky Mats
Testing and Monitoring
Calibration Units
Continuous Monitors
Dual Wire Resistance Monitors
Single Wire AC Capacitance Monitors
Field Meters
Periodic Wrist Strap and Footwear Testers
Combo Wrist Strap & Footwear Testers
Footwear Testers
Closeout Testers and Monitors
Trustat®
Grounding Products
Heel Grounders
Ionizers
Smocks
Worksurface Mats
Wrist Straps and Coil Cords
Workstation Accessories
Dissipative Chair Cover
Workstation Mats
Dissipative Rubber Mat
Tray Liners
Mat Kits
Factory Closeouts
Closeout - Workstation Mats
Closeout - Accessories
Closeout Foot Grounders
Closeout Smocks, Gloves, and Finger Cots
Closeout - Packaging and Handling
Closeout Antistatic Tape
Closeout Labels
Closeout Metal In Bags
Closeout ESD Bags
Closeout Workstation Pouches
Closeout Testers and Monitors
Closeout Wrist Straps and Coil Cords
Closeout - Miscellaneous Coil Cords
Closeout - 4mm Single Wire Wrist Straps and Coil Cords
Closeout - 4mm Dual Wire Wrist Straps and Coil Cords
Closeout - 7mm Single Wire Wrist Straps and Coil Cords
Closeout - 7mm Dual Wire Wrist Straps and Coil Cords
Closeout - 10mm Single Wire Wrist Straps and Coil Cords
Closeout - 10mm Dual Wire Wrist Straps and Coil Cords
New Products
Resources
Overstock
REGISTER / LOGIN
SHOP
CART (
0
)
SUBSCRIBE TO OUR EMAIL LIST - Be the first to know
about exclusive deals, tips, new products & more!
Questions And Answers
#
55
List All Questions
Search
List by Category
Question
Static shocks are rebooting computers at 17 - 20 feet away during the winter months (seems like when heat is on). Have you heard of this? (I need data 'proof' that this can cause damage at distances) What product solutions do you have? - Anonymous, Fort Polk, LA
Answer
It sounds like you have several things that could contribute to your problem: severe triboelectric generation from mobile people - solution: implement ESD/Antistatic floor and ESD foot wear. Conductive surfaces allowing quick and high energy discharges - solution: implement grounded static dissipative mats & coatings on very conductive surfaces. A very dry environment, further increasing the risks of ESD - solution: implement humidity control or air ionization at critical areas. Product solutions: Employee a static dissipative and more importantly antistatic floor finish or covering all affected areas. We would recommend floor finish as it has excellent antistatic properties. Combine this with ESD foot wear such as a foot grounder. These two products combined will greatly reduce the triboelectric charging that may be one of the larger factors in generation of static shocks. Apply Reztore® Topical Antistat to all surfaces that are not dissipative. Replace all conductive surfaces (<1x10^4 Ohms) with dissipative ones or cover the conductive surfaces with dissipative materials. Make sure all these conductive (dissipative) surfaces are grounded as well as the operators (foot grounders, wrist straps, etc.). By replacing the very conductive surfaces with a higher resistant material, you minimize the energy transferred during an ESD and reduce or eliminate a problem EMI.