   Dr. ZAP
Air Ionization

 

Setting up an ESD-safe workstation is often more challenging than it first appears. There are many methods of controlling ESD, and typically, it requires a combination of these to curb all static problems. Unfortunately, there is no single method that will fill all requirements.

Wrist straps and work surface mats are probably the most familiar to us, draining charges from operators as well as from the product being worked on, but what if the static charge in question is on an insulator? Electronic products, by nature, will normally consist of conductors and insulators. Insulators at the workstation can be found on the product itself, tools being used, tapes for masking, even circuit boards. A static charge on an insulator cannot be drained by grounding, as you could with a conductive material.

What can we do?

To effectively remove charges from insulators, we need to make the surrounding air more conductive. We have all seen a balloon cling to a wall because of a static charge, and we know that, after a period of time, it will drop. That is because the air is somewhat conductive and the charge eventually drains off. The problem with this concept is that it takes too long. The more conductive the air is, the faster the charge will be neutralized.

The two methods most frequently used to increase the conductivity of the air are - increasing the relative humidity level and air ionization. In many applications, increasing the relative humidity creates a host of new problems, such as: operator discomfort, causing metals to oxidize or rust, solderability problems, and the high cost and difficulty in maintaining the desired level. For these reasons, air ionization has become the method of choice.

Air ionization

The four major type of ionizers are AC, pulsed DC, steady-state DC, and nuclear. The focus of this article will be on the first three types, which use electricity to create ions. The nuclear types, which are non-electric, are more frequently used in flammable or explosive environments for applications other than electronics.

Electrical ionizers generate air ions by a process known as corona discharge. A high voltage is applied to one or more sharp points and quantities of air ions are created. Fans or blowers may be incorporated in the ionizer to assist the movement of the ions and enhance performance.

AC ionizers use a transformer to multiply the AC power line voltage. AC stands for Alternating Current, which means that the power cycles from positive to negative sixty times per second. The AC ionizer therefore produces both positive and negative ions from the same points or emitters. The drawback with this approach is that many ions recombine because the cycle frequency is too fast. For this reason, most AC ionizers rely on fans or blowers to be effective.

Pulsed DC ionizers utilize separate power supplies to generate positive and negative voltages and usually each power supply has it's own dedicated emitters. The power supply alternates between positive and negative, but usually at a lower frequency than AC units. In this way, ion recombination is reduced and performance is increased. Airflow may then be reduced for operator comfort without sacrificing much performance. With pulsed DC, it is important to cycle at least two or three times per second to prevent harmful voltage swings on the object being protected.

Steady-state DC ionizers also employ separate power supplies and emitters, but instead of alternating positive and negative, both supplies are on all the time as the name implies. As would be expected, there is some degree of recombination, however, the ion density is still greater because of continuous operation of both supplies. The offset or balance voltage at the output will normally be more consistent than pulse units.

The Selection Process

Ionizer configurations range from elaborate systems that blanket an entire room to small palm-sized units. Selection of ionization equipment depends on the application, the space available, the performance desired, and what features are important. A single model may be well suited to one application, and useless in another. Fortunately, there are many models on the market to choose from.

Room ionization will typically have multiple emitters just below ceiling height and will rely on some amount of air movement for moving the ions down to bench level. Room ionization was considered by some to be the most effective way to protect large areas against ESD hazards. Current thinking is leaning more toward localized workstation ionization. There are several reasons for this. Product sensitivity has become much greater and long decay times of room ionization cannot be tolerated. Often, with room ionization, only a fraction of the ionized area may be ESD sensitive. Localized ionizers bring protection to the areas where it's needed and performance is often 10 times faster than the ceiling height system. Additionally, localized ionization moves with the workstation, or to a new workstation, making it much more flexible with changing production line layouts.

Workstation ionizers can be found in many shapes and sizes. The most common of these is the benchtop ionizer, which is about the size of two phone books stacked up. These models are the original workhorses for the bench and are still in high demand. As the market matured, smaller, lighter units began to appear. Because bench top real estate is valuable, many users prefer the smaller ionizers. Some small ionizers are suspended above the bench using a flexible, articulated arm mounting method. Whatever style is chosen, care should be taken to assure that items normally on the bench would not obstruct the flow of ionized air.

Overhead ionization was conceived to solve the obstacle blocking the ionizer problem. The overhead ionizer typically will be suspended 18 to 24 inches above the bench either by hanging from chains, or by mounting brackets to the bench or shelf. With this method of ionization, it is very unlikely that an object will block the flow of ionized air to the item being protected. In addition, the downward airflow is more consistent over the entire bench. To assure that adequate air is delivered, normally 2 to 4 fans are used in a package ranging from 24 to 48 inches long.

Focused air ionizers are often used where the process demands small area or spot protection. They are either hand-held similar to an air nozzle or they may be mounted in a fixed location. The main advantage of this type is that the user has the benefit of a strong air blast (20 to 100 P.S.I.) to help dislodge contamination, while the ionization in the air stream eliminates the static attraction of the particles at the same time. Hand-held air nozzle types will usually have a trigger or pushbutton to activate the air and ion flow, while the stationary-mounted type is frequently remote controlled with a foot pedal, photo sensor, or some other switch closure.

Industrial ionization, while not normally used for electronic work, also deserves mention, as it uses basically the same technology (usually AC ionization). This segment of the market is more related to processing materials and eliminating the undesirable static cling. Many processes such as injection molding, printing, film converting, and similar operations have serious problems with electrostatic attraction. Due to the fact that these processes are frequently fast moving, the normal bench-type ionizer will not keep pace. Instead, for these applications, large blowers or manifolds of compressed air are used to propel the ions. More often than not, the blowers or ionizing bars are placed in close proximity to the object with the charge for maximum benefits. By using industrial ionizers, many processes have improved yields, speed, and safety.

Features are important to consider when selecting an ionizer. If the unit is to be located at a bench, operator comfort is important. Some models have heaters built in to eliminate the "chill effect" of blowing air. Others have speed controls for the fans to tailor the airflow. Lights are sometimes incorporated with the ionizer to add additional illumination to the bench. Top of the line models will generally have some form of electronically controlled balance indicator to display the status of the ionizer, as well as automatic shutdown protection in the event of a problem. Some ionizers even have indicators signaling when cleaning or maintenance is required.

Maintenance is a requirement on virtually all ionizers to assure continued performance. Contamination will collect on the sharp emitter points, which must be cleaned away on a regular schedule. The contaminant build-up on the emitter can normally be removed with a soft brush, however, sometimes a more thorough cleaning is necessary using a swab and alcohol to remove tough deposits. The cleaning frequency is different for every application, however, the interval can be determined by using a charged plate analyzer. This piece of equipment is made specifically for evaluating ionizers. In addition to measuring balance of the ionized field, the analyzer will measure the decay performance. The charged plate analyzer applies a known voltage to the isolated plate and measures the time it takes for the ionizer to reduce the charge to a certain value. It's important to note that a manufacturer's claim that the unit always stays in balance is meaningless. An ionizer with no ion output can appear to be in balance. The decay performance must be checked to see the whole picture. By using the charged plate analyzer at regular intervals, the user can determine the proper maintenance interval when a drop in performance is noted.

In conclusion, ionization is one of the best methods of removing charges from insulators, and as a result plays an important role in controlling ESD. Remember, though, that the ionizer is a secondary form of defense and does not eliminate the need for standard ESD control devices, such as wrist straps, heel grounders, and work surface mats. It is only one element in an effective ESD program.

  PRODUCT UPDATES

Yellow Opaque Antistatic Tape with Symbols

Yellow Antistatic Tape w/Symbols
Length: 72 YDS
Widths: 1/2", 3/4", 1" & 2"
Core: 3" Diameter
  
  • Safe identification or marking of product, paperwork and processes
  • Ideal for securing static safe packaging
  • High visibility yellow color with ESD susceptibility symbol for increased awareness
  • Opaque color still remains bright yellow when affixed to darker items
  • Attach ESD paperwork to bags or product
  • Ideal in packaging for container sealing, static shielding bag closure and holding IC DIP tubes
  • Helps prevents damage to sensitive electronic components in manufacturing

Buy Now    Tech Info 

  


FRP Mats
FRP Dissipative Mats

  • Durable fiber reinforced polyester ESD protective material is resistant to most chemicals
  • Volume dissipative, reversible - will electrically couple
  • Low coefficient of friction - ideal to slide or rotate assemblies; premium choice for chair mats
  • Temperature rating range of 0F - 300F
  • Excellent for use in soldering or conformal coating applications
  • Cut resistant hard surface is ideal for trimming workstations
  • RTT: 105- 108 ohms

Buy Now    Tech Info 

  

New Catalog Fall 2000

Don't forget to request your new catalog from our on-line catalog request form by clicking here.

You can also visit our on-line catalog 24/7 by clicking here.



ESD Systems.com Catalog Cover

 

 

 

Our products come with full technical support

Product document support includes a technical brief, drawing or bulletin. These are referenced within our on-line catalog as well as listed in our web site.

 

Technical Brief
 EtroniX (NepCon West)  Click here for more
When:Feb 27 - Mar 1, 2001
Where:Anaheim Convention Center, Anaheim, CA, USA
What:EtroniX features a family of industry related events - covering design, e-manufacturing, advanced packaging, production, test and more - all under one roof.
Why:Visit us at our Booth, # T-2249
  ESD Q & A CORNER

Q40: Static charges are a real problem in the printing industry. Paper picks up a charge when run through the press. When the same paper is rerun through the press, it has enough charge in the paper to make it try to stick together creating a real feed problem. Do you have any experience in this area?. - Anonymous, Houston, TX  see ANSWER 40

Q88: I would like to know more about ionizer to dissipate [neutralize] the charges on PVC or plastics materials. - Anonymous, Singapore  see ANSWER 88

Q400: Is air ionization an effective way to neutralize static charges on the surfaces of insulators by means of corona discharge? Does time play a factor in the amount of air volume that can be ionized? If so, what procedures can be taken to speed up the movement of the ions? -Anonymous    see ANSWER 400

Find more ESD Q&As here

 

NOTE:
If you haven't already done so, downloading Acrobat Reader is highly recommended as most of our Technical Literature is in an electronic form known as portable document files (PDF files). These can be e-mailed or downloaded from our website, however you'll need Adobe Acrobat Reader to view them.

The good news is that this program is free. Adobe Acrobat can be downloaded from Adobe's website. The file is over 3 megs, so be sure you have the capacity to receive that large a file.

  MONTHLY HOT TIP
Antistatic & other Confusing Terms:

A long time ago, antistatic had meant a high resistance range and then later had been coined to mean low tribocharging. Neither of which are really correct today. The correct term to use for low tribocharging is not "antistatic" but rather "Low Charging". The ESD Association is now adapting this term into its documents in lieu of "antistatic".

Ohms per what? Another term that has incorrectly been used is a unit for surface resistivity, ohms per square or ohm-sq. In ESD control, the proper unit of resistance or resistivity is just the unit of ohm. Refer to an earlier article written by Mr. Static in the ESD Association's Threshold as well as look for a new article by Gene Chase on this matter.

ESD SYSTEMS.com HELP SECTION
NEW ON-LINE CATALOG:
Click here to enter the ESD Store

TECH SUPPORT:
support@esdsystems.com

FAX YOUR ORDERS:
800-805-5665

TELEPHONE:
508-485-7390

ASK AN ESD QUESTION:
Click here to ask a technical question

CUSTOMER SERVICE & SALES QUESTIONS:
service@esdsystems.com

YOUR PERSONAL INSIDE SALES REP:
http://www.esdsystems.com/contacts.html
WEB: http://www.esdsystems.com/

Change of e-mail address:
Email "service@esdsystems.com" with both your old and new e-mail addresses.

Need your own copy? Want to subscribe to this Newsletter? All you or your colleague(s) need to do is simply fill out the subscription form at http://www.esdsystems.com/forms/esdmail.asp

Want to remove yourself from this e-mail list:
To unsubscribe from this mailing, send an e-mail to ESD_Corner@esdsystems.com and put "UNSUBSCRIBE ESD_Newsletters" in the body.

Still having trouble getting off this e-mail list:
E-mail "removelist@esdsystems.com" with your e-mail addresses for manual processing.

This is a free monthly e-newsletter, which specializes on issues in static control in the semiconductor/electronics workplace and is best viewed while connected to the Internet.

Let us know what you think. Tell us what you would like to see in future issues. Want to contribute articles or other related information to our Newsletter? If you have any comments, suggestions or feedback about this newsletter, please send them directly to the editor@esdsystems.com, thanks.

Copyright © 2000 ESD Systems.com. All rights reserved.